Multi-function card EX701 instructions
Function card appearance image:
Interface instruction:
Note: extend photoconductive resistance and temperature and humidity detector, power positive/negative don't connect the reverse
1, remote control display power supply
A signal transmission to functional CARDS, function card terminal will produce circuit, power1/power 2/power 3 can use this function(below in figure 3) .FAN1, FAN2 used to control fan, air conditioner
2. Internal temperature and humidity, external temperature and humidity
Internal temperature, humidity detection cabinet of temperature and humidity inside.
The external temperature, humidity by to show humidity/temperature on led display.
3. Automatic brightness to adjust
According to photoconductive resistance to detect changes to the environment brightness data automatically adjust the brightness of the LED.
4. Voice transmission (send card type is to be baled TS802)
From computer soundcards to connect send card (audio line), send cards again through cable or a fibre to function card, again output by function card’s audio output.
5.Connections
Function card placed between in sending CARDS and the first piece of receiving card .
6. Functions card automatic brightness to adjust
LED studio version to 10.98 or above
1. The first open LED studio, click Settings - software Settings - on the keyboard input "linsn" - password 168 into receiving card set interface
Press linsn, will show below window:
password:168
Choose to allow function card brightness options, save to send card.
2.
Choose to allow brightness automatic adjustment is let functional card according to external environment brightness to adjust brightness LED screens.
7. Parameters set
Brightness values: the current LED brightness levels (256 levels of, 0-255)
Minimum brightness values: users LED screens of preset minimum brightness values
Sensitivity: the higher sensitivity, slight changes caused environmental brightness LED screens brightness changes
Sampling speed: faster, LED big screen brightness adjusting reaction faster
Internal temperature: the internal temperature detector detect temperature
The external temperature: external temperature detector temperature detection
Fixed: fixed outside temperature (such as 37 degrees) and temperature probe measurement temperature (for example 36.5 degrees) error. Then the modifier for: 0.5
Fan open temperature: according to internal temperature probe detected temperature, temperature data to open, automatic open fan.
Fan state: display the current fan is open or closed
Air conditioning open temperature: according to internal temperature probe detected temperature, temperature data to open, automatic open air conditioning.
Air conditioning state: display the current air conditioning is open or closed
Note: automatic open function will fan or air conditioning through the ac contactor connected to the corresponding function card power relay connector. (as shown)
Temperature in Celsius temperature unit: display in degrees or Fahrenheit
Internal humidity: internal humidity detector detect humidity value
External humidity: external humidity detector detect humidity value
Smoke (function has not been perfected yet)
Smoke value: smoke detectors detection data value
Alarm value: the preset a alarm smoke detectors detection data value
Alarm is closed screen power: alarm is closed the LED display power supply
Alarm condition: the current alarm condition
Switch manual control
Mandatory manual: through the manual on/off function card five power relay connector
Renamed: changes every power relay name, the convenient user identification management each power connector corresponding appliances.
Note: choose after compulsory manual, under the Settings menu ,to close led display power supply function failure .
END。